Loring S

1. Connecting the roasting machine and computer

Please prepare a LAN cable. Connect the roaster and the computer with a LAN cable.

2. Setting up the network

1. To set up a static IP address on your PC, you must first go to the Ethernet Settings menu. Windows 7, 8: Start -> Control Panel -> Network and Internet -> Network and Sharing Center → Select Change adapter settings on the left.

Windows 10: Open Settings -> Network & Internet → Select Change adapter settings on Ethernet Tap

2. Next, in the Network Connections window, right-click on the Network connection associated with your Ethernet adapter and click Properties

3. Click on Internet Protocol Version 4 (TCP/IPv4)

  1. Enter the IP address, subnet mask, and gateway IP referring to the table below.

NameIP AddressSubnet MaskGateway

Loring

192.168.1.42

255.255.255.0

blank

3. Setting in Firescope

1. Launch Firescope and enter the Machine page. Click the Add New Machine button.

2. Fill in the Nickname, Manufacturer, and Temperature inputs. When selecting a preset, click the appropriate one between Loring S.

3. In Network IP, enter IP below, and keep the port as 502 unless it is a special case.

  • S15 Falcon, S35 Kestrel and S70 Peregrine: 192.168.1.199

  • S7 Nighthawk: 192.168.1.69

4. If you have registered normally in the above process, you can get the machine's sensor values ​​within 10 seconds.

If you have difficulty connecting to the roasting machine, Please send an email to jason@firescope.io